  3. Comparison of corneal measurements in keratoconus eyes with two swept-source-optical coherence tomography devices and a Scheimpflug device.

Comparison of corneal measurements in keratoconus eyes with two swept-source-optical coherence tomography devices and a Scheimpflug device.

Details
Files
DOI
10.48350/186204
Publisher DOI
10.1007/s00417-023-06219-6
PubMed ID
37688609
Abstract
PURPOSE

To assess the feasibility and reliability of biometric measurements taken with the Eyestar 900 device in keratoconus eyes in comparison with those taken with the Pentacam HR and IOLMaster 700.

METHODS

Seventy-five eyes of 75 patients with keratoconus were included. The central corneal thickness (CCT), thinnest point of corneal thickness (TCT), axial length (AL), flat (K1) and steep (K2) anterior and posterior (Kp1, Kp2) keratometry, maximal keratometry (KMax) and anterior chamber depth (ACD) were compared between the Eyestar 900, Pentacam HR and IOLMaster 700. Reliability parameters such as the coefficient of variation (CoV) and intraclass correlation coefficient (ICC) were calculated. Pearson's r was determined to assess the correlation between devices.

RESULTS

A high repeatability (CoV < 1%) and intraclass correlation (ICC > 0.9) was found for all devices, led by AL, TCT, K1 and K2 (CoV 0.01-0.36%; ICC 0.994-1.00). The largest correlation between devices was found for AL (Eyestar vs. IOLMaster, r = 1.0), K1 (Eyestar vs. IOLMaster, r = 0.997) and ACD (Eyestar vs. IOLMaster, r = 0.995; Pentacam vs. IOLMaster, r = 0.987; Eyestar vs. Pentacam, r = 0.983), but there were significant differences in measured values between devices (p < 0.001), whereas the correlation was only slightly lower (r = 0.947 to 0.994) for KMax, CCT, TCT, K2, Kp1 and Kp2.

CONCLUSION

Keratometric and axial length measurements with the Eyestar 900 were feasible and revealed a high repeatability and a good correlation to the other devices in eyes with keratoconus.
Date Issued
2024-03
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Subjects
Comparison Eyestar IOLMaster Keratoconus Keratometry Pentacam
Language(s)
en
Author(s)
Bograd, Alexandra Emma Olga  
Universitätsklinik für Augenheilkunde  
Himmel, Isabelle
Pfister, Isabel B
Seiler, Günter Theodor Michael  
Universitätsklinik für Augenheilkunde  
Früh Epstein, Beatrice  
Universitätsklinik für Augenheilkunde  
Tappeiner, Christoph  orcid-logo
Universitätsklinik für Augenheilkunde  
Additional Credits
Universitätsklinik für Augenheilkunde  
Journal
Graefe's archive for clinical and experimental ophthalmology
Publisher
Springer
ISSN
1435-702X
Related URL(s)
https://boris.unibe.ch/186823/
Access(Rights)
restricted
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 24f0a9 [ 4.09. 8:55]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • BORIS Portal & Open Science
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo
Repository logo COAR Notify