• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Quality assurance of radiotherapy in the ongoing EORTC 1420 "Best of" trial for early stage oropharyngeal, supraglottic and hypopharyngeal carcinoma: results of the benchmark case procedure.

Quality assurance of radiotherapy in the ongoing EORTC 1420 "Best of" trial for early stage oropharyngeal, supraglottic and hypopharyngeal carcinoma: results of the benchmark case procedure.

Details
Files
DOI
10.48350/156517
Publisher DOI
10.1186/s13014-021-01809-2
PubMed ID
33933118
Abstract
INTRODUCTION

The current phase III EORTC 1420 Best-of trial (NCT02984410) compares the swallowing function after transoral surgery versus intensity modulated radiotherapy (RT) in patients with early-stage carcinoma of the oropharynx, supraglottis and hypopharynx. We report the analysis of the Benchmark Case (BC) procedures before patient recruitment with special attention to dysphagia/aspiration related structures (DARS).

MATERIALS AND METHODS

Submitted RT volumes and plans from participating centers were analyzed and compared against the gold-standard expert delineations and dose distributions. Descriptive analysis of protocol deviations was conducted. Mean Sorensen-Dice similarity index (mDSI) and Hausdorff distance (mHD) were applied to evaluate the inter-observer variability (IOV).

RESULTS

65% (23/35) of the institutions needed more than one submission to achieve Quality assurance (RTQA) clearance. OAR volume delineations were the cause for rejection in 53% (40/76) of cases. IOV could be improved in 5 out of 12 OARs by more than 10 mm after resubmission (mHD). Despite this, final IOV for critical OARs in delineation remained significant among DARS by choosing an aleatory threshold of 0.7 (mDSI) and 15 mm (mHD).

CONCLUSIONS

This is to our knowledge the largest BC analysis among Head and neck RTQA programs performed in the framework of a prospective trial. Benchmarking identified non-common OARs and target delineations errors as the main source of deviations and IOV could be reduced in a significant number of cases after this process. Due to the substantial resources involved with benchmarking, future benchmark analyses should assess fully the impact on patients' clinical outcome.
Date Issued
2021-05-01
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Subjects
Benchmark case EORTC 1420 Best-of trial Organs at risk Swallowing
Language(s)
en
Author(s)
Stelmes, J-J
Vu, E
Grégoire, V
Simon, C
Clementel, E
Kazmierska, J
Grant, W
Ozsahin, M
Tomsej, M
Vieillevigne, L
Fortpied, C
Hurkmans, E C
Branquinho, A
Andratschke, N
Zimmermann, F
Weber, Damien Charles  
Universitätsklinik für Radio-Onkologie  
Additional Credits
Universitätsklinik für Radio-Onkologie  
Journal
Radiation oncology
Publisher
BioMed Central
ISSN
1748-717X
Access(Rights)
Unknown
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 0eaa7c [ 7.08. 11:06]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • BORIS Portal & Open Science
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo
Repository logo COAR Notify