• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Positional accuracy during the sequence of static computer-assisted implant surgery in three alveolar ridge morphologies: an in vitro study.

Positional accuracy during the sequence of static computer-assisted implant surgery in three alveolar ridge morphologies: an in vitro study.

Details
Files
DOI
10.48350/188863
Publisher DOI
10.1111/jopr.13798
PubMed ID
37955870
Abstract
PURPOSE

This in vitro study aimed to assess the positional accuracy during the sequence of static Computer-Assisted Implant Surgery (sCAIS) according to the anatomical characteristics of the alveolar ridge.

MATERIAL AND METHODS

Maxillary bone models with six single tooth gaps including clinical scenarios of healed alveolar ridge (HR), single-rooted (SRS), and three-rooted socket (TRS) morphologies were used in this study. Positional deviations during implant placement procedures were evaluated after the pilot osteotomy (PD), final osteotomy (FD), and implant placement with respect to the pre-planned implant position by using a software package. ANOVA and post hoc analyses were performed.

RESULTS

Ninety implants were included in this study. Higher mean angular, crestal, and apical deviations were found after the PD and FD (3.5 ±2.4°, 0.7 ±0.3mm, and 1.4 ±0.8mm versus 3.6 ±2.2°, 0.6 ±0.3mm, and 1.2 ±0.6mm) compared to IP (2.8 ±1.6°, 0.7 ±0.3mm, and 1.2 ±0.5mm, p≤0.004). Implants placed in TRS demonstrated higher mean angular, crestal, and apical deviations (4.0 ±1.7°, 0.8 ±0.3mm, and 1.6 ±0.5mm) compared to implants placed in SRS (2.5 ±1.2°, 0.7 ±0.3mm, and 1.1 ±0.4mm) or HR (2.0 ±0.9°, 0.5 ±0.3mm, and 0.8 ±0.4mm, p<0.001).

CONCLUSIONS

Positional deviations during sCAIS procedures are initiated with the first implant osteotomy and persist throughout the drilling sequence. However, deviations slightly decreased after implant placement. The alveolar ridge morphology is strongly associated with positional deviations. Higher deviations were observed in three-rooted and single-rooted sockets simulating an immediate approach compared to healed sites simulating a delayed protocol. This article is protected by copyright. All rights reserved.
Date Issued
2025
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Subjects
alveolar ridge clinical decision-making dental implants image-guided surgery single tooth tooth extraction
Language(s)
en
Author(s)
Raabe, Clemens  
Zahnmedizinische Kliniken (ZMK) Universität Bern  
Zahnmedizinische Kliniken (ZMK) - Klinik für Oralchirurgie und Stomatologie  
Abou-Ayash, Samir  
Zahnmedizinische Kliniken (ZMK) - Klinik für Rekonstruktive Zahnmedizin und Gerodontologie  
Yilmaz, Burak  
Zahnmedizinische Kliniken (ZMK) - Klinik für Rekonstruktive Zahnmedizin und Gerodontologie  
Zahnmedizinische Kliniken (ZMK) - Klinik für Zahnerhaltung, Präventiv- und Kinderzahnmedizin  
Surbek, Fiona Jennifer
Chappuis, Vivianne  
Zahnmedizinische Kliniken (ZMK) - Klinik für Oralchirurgie und Stomatologie  
Couso Queiruga, Emilio  orcid-logo
Zahnmedizinische Kliniken (ZMK) Universität Bern  
Zahnmedizinische Kliniken (ZMK) - Klinik für Oralchirurgie und Stomatologie  
Additional Credits
Zahnmedizinische Kliniken (ZMK) - Klinik für Oralchirurgie und Stomatologie  
Zahnmedizinische Kliniken (ZMK) - Klinik für Zahnerhaltung, Präventiv- und Kinderzahnmedizin  
Zahnmedizinische Kliniken (ZMK) Universität Bern  
Zahnmedizinische Kliniken (ZMK) - Klinik für Rekonstruktive Zahnmedizin und Gerodontologie  
Journal
Journal of prosthodontics
Publisher
Wiley
ISSN
1532-849X
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 24f0a9 [ 4.09. 8:55]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • BORIS Portal & Open Science
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo
Repository logo COAR Notify