  3. The Forensic Reference Phantom-a new tool for quality assurance of attenuation measurements in forensic radiology

The Forensic Reference Phantom-a new tool for quality assurance of attenuation measurements in forensic radiology

Details
Publisher DOI
10.1016/j.jofri.2013.03.043
Abstract
Introduction

The purpose of this paper is to present the technical specifications of the Forensic Reference Phantom (FRP), to test its behavior relative to organic test materials, and discuss potential applications of the phantom in forensic radiology.
Materials and method

The FRP prototype is made of synthetic materials designed to simulate the computed tomography (CT) attenuation of water. It has six bore holes that accommodate multiuse containers. These containers were filled with test materials and scanned at 80 kVp, 120 kVp, and 140 kVp. X-ray attenuation was measured by two readers. Intra- and inter-reader reliability was assessed using the intra-class correlation coefficient (ICC). Significance levels between mean CT numbers at 80 kVp, 120 kVp, and 140 kVp were assessed with the Friedman-test. The T-test was used to assess significance levels between the FRP and water.
Results

Overall mean CT numbers ranged from −3.0–3.7HU for the FRP; −1000.3–−993.5HU for air; −157.7– −108.1HU for oil; 35.5–42.0HU for musle tissue; and 1301.5–2354.8HU for cortical bone. Inter-reader and intra-reader reliability were excellent (ICC>0.994; and ICC=0.999 respectively). CT numbers were significantly different at different energy levels. There was no significant difference between the attenuation of the FRP and water.
Conclusions

The FRP is a new tool for quality assurance and research in forensic radiology. The mean CT attenuation of the FRP is equivalent to water. The phantom can be scanned during routine post-mortem CT to assess the composition of unidentified objects. In addition, the FRP may be used to investigate new imaging algorithms and scan protocols in forensic radiology.
Date Issued
2013
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Subjects
Forensic radiology
•
Computed tomography
•
Phantom
•
X-ray attenuation
•
Virtopsy
Language(s)
en
Author(s)
Ruder, Thomas  
Institut für Diagnostische, Interventionelle und Pädiatrische Radiologie  
Hatch, Gary M.
Ebert, Lars
Thali, Yannick
Allmendinger, Thomas
Schindera, Sebastian T.
Dalla Torre, Simon A.
Gascho, Dominic
Thali, Michael J.
Ampanozi, Garyfalia
Additional Credits
Institut für Diagnostische, Interventionelle und Pädiatrische Radiologie  
Journal
Journal of Forensic Radioloy and Imaging
Publisher
Elsevier
ISSN
2212-4780
Access(Rights)
metadata.only
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 24f0a9 [ 4.09. 8:55]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • BORIS Portal & Open Science
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo
Repository logo COAR Notify