Abstract
OBJECTIVE

Comparison of a fully-automated segmentation method that uses compartmental volume information to a semi-automatic user-guided and FDA-approved segmentation technique.

METHODS

Nineteen patients with a recently diagnosed and histologically confirmed glioblastoma (GBM) were included and MR images were acquired with a 1.5 T MR scanner. Manual segmentation for volumetric analyses was performed using the open source software 3D Slicer version 4.2.2.3 (www.slicer.org). Semi-automatic segmentation was done by four independent neurosurgeons and neuroradiologists using the computer-assisted segmentation tool SmartBrush® (referred to as SB), a semi-automatic user-guided and FDA-approved tumor-outlining program that uses contour expansion. Fully automatic segmentations were performed with the Brain Tumor Image Analysis (BraTumIA, referred to as BT) software. We compared manual (ground truth, referred to as GT), computer-assisted (SB) and fully-automated (BT) segmentations with regard to: (1) products of two maximum diameters for 2D measurements, (2) the Dice coefficient, (3) the positive predictive value, (4) the sensitivity and (5) the volume error.

RESULTS

Segmentations by the four expert raters resulted in a mean Dice coefficient between 0.72 and 0.77 using SB. BT achieved a mean Dice coefficient of 0.68. Significant differences were found for intermodal (BT vs. SB) and for intramodal (four SB expert raters) performances. The BT and SB segmentations of the contrast-enhancing volumes achieved a high correlation with the GT. Pearson correlation was 0.8 for BT; however, there were a few discrepancies between raters (BT and SB 1 only). Additional non-enhancing tumor tissue extending the SB volumes was found with BT in 16/19 cases. The clinically motivated sum of products of diameters measure (SPD) revealed neither significant intermodal nor intramodal variations. The analysis time for the four expert raters was faster (1 minute and 47 seconds to 3 minutes and 39 seconds) than with BT (5 minutes).

CONCLUSION

BT and SB provide comparable segmentation results in a clinical setting. SB provided similar SPD measures to BT and GT, but differed in the volume analysis in one of the four clinical raters. A major strength of BT may its independence from human interactions, it can thus be employed to handle large datasets and to associate tumor volumes with clinical and/or molecular datasets ("-omics") as well as for clinical analyses of brain tumor compartment volumes as baseline outcome parameters. Due to its multi-compartment segmentation it may provide information about GBM subcompartment compositions that may be subjected to clinical studies to investigate the delineation of the target volumes for adjuvant therapies in the future.
Date Issued
2016-11-02
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
500 Science > 570 Life sciences; biology
Language(s)
en
Author(s)
Porz, Nicole  
Universitätsinstitut für Diagnostische und Interventionelle Neuroradiologie  
Habegger, Simon  
Universitätsinstitut für Diagnostische und Interventionelle Neuroradiologie  
Meier, Raphael  
Institut für chirurgische Technologien und Biomechanik (ISTB)  
Verma, Rajeev Kumar  
Universitätsinstitut für Diagnostische und Interventionelle Neuroradiologie  
Jilch, Astrid  
Universitätsklinik für Neurochirurgie  
Fichtner, Jens  
Universitätsklinik für Neurochirurgie  
Knecht, Urspeter  
Universitätsinstitut für Diagnostische und Interventionelle Neuroradiologie  
Radina, Christian
Schucht, Philippe  
Universitätsklinik für Neurochirurgie  
Beck, Jürgen  
Universitätsklinik für Neurochirurgie  
Raabe, Andreas  
Universitätsklinik für Neurochirurgie  
Slotboom, Johannes  
Universitätsinstitut für Diagnostische und Interventionelle Neuroradiologie  
Reyes Aguirre, Mauricio Antonio  
Institut für chirurgische Technologien und Biomechanik (ISTB)  
Wiest, Roland Gerhard Rudi  
Universitätsinstitut für Diagnostische und Interventionelle Neuroradiologie  
Additional Credits
Institut für chirurgische Technologien und Biomechanik (ISTB)  
Universitätsinstitut für Diagnostische und Interventionelle Neuroradiologie  
Universitätsklinik für Neurochirurgie  
Journal
PLoS ONE
Publisher
Public Library of Science
ISSN
1932-6203
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 24f0a9 [ 4.09. 8:55]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • BORIS Portal & Open Science
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo
Repository logo COAR Notify