Publication:
An automated pipeline for computation and analysis of functional ventilation and perfusion lung MRI with matrix pencil decomposition: TrueLung.

cris.virtual.author-orcid0000-0003-1140-9437
cris.virtual.author-orcid0000-0003-1840-3118
cris.virtual.author-orcid0000-0002-5239-1571
cris.virtualsource.author-orcid712df019-44db-4ab1-ae43-cbeae43f7042
cris.virtualsource.author-orcidc78a191b-4014-4c0e-9c6f-c43327df9b50
cris.virtualsource.author-orcidb49607d2-d0cc-47e2-8d6a-7d58ce7fb616
cris.virtualsource.author-orcid7457a40a-9226-489a-9650-a936c14fb53f
cris.virtualsource.author-orcid7d4eb2d1-f3c9-4752-9d7e-db0095edec5c
datacite.rightsopen.access
dc.contributor.authorPusterla, Andrea Orso
dc.contributor.authorWillers, Corin
dc.contributor.authorSandkühler, Robin
dc.contributor.authorAndermatt, Simon
dc.contributor.authorNyilas, Sylvia
dc.contributor.authorCattin, Philippe C
dc.contributor.authorLatzin, Philipp
dc.contributor.authorBieri, Oliver
dc.contributor.authorBauman, Grzegorz
dc.date.accessioned2024-10-29T14:57:04Z
dc.date.available2024-10-29T14:57:04Z
dc.date.issued2024-09-19
dc.description.abstractPurpose To introduce and evaluate TrueLung, an automated pipeline for computation and analysis of free-breathing and contrast-agent free pulmonary functional magnetic resonance imaging.Materials And Methods Two-dimensional time-resolved ultra-fast balanced steady-state free precession acquisitions were transferred to TrueLung, which included image quality checks, image registration, and computation of perfusion and ventilation maps with matrix pencil decomposition. Neural network whole-lung and lobar segmentations allowed quantification of impaired relative perfusion (R) and fractional ventilation (R). TrueLung delivered functional maps and quantitative outcomes, reported for clinicians in concise documents. We evaluated the pipeline using 1.5T data from 75 children with cystic fibrosis by assessing the feasibility of functional MR imaging, average scan time, and the robustness of the functional outcomes. Whole-lung and lobar segmentations were manually refined when necessary, and the impact on R and R was quantified.Results Functional imaging was feasible in all included CF children without any dropouts. On average, 7.9 ± 1.8 (mean±SD) coronal slice positions per patient were acquired, resulting in a mean scan time of 6min 20s per patient. The whole pipeline required 20min processing time per subject. TrueLung delivered the functional maps of all the subjects for radiological assessment. Quality controlling maps and segmentations lasted 1min 12s per patient. The automated segmentations and quantification of whole-lung defects were satisfying in 88% of patients (97% of slices) and the lobar quantification in 73% (93% of slices). The segmentations refinements required 16s per patient for the whole-lung, and 2min 10s for the lobe masks. The relative differences in R and R between fully-automated and manually refined data were 0.7% (1.2%) and 2.0% (2.9%) for whole-lung quantification (median, [third quartile]), and excluding two outliers, 1.7% (3.9%) and 1.2% (3.8%) for the lobes, indicating the refinements could be potentially omitted in several patients.Conclusions TrueLung quickly delivers functional maps and quantitative outcomes in an objective and standardized way, suitable for radiological and pneumological assessment with minimal manual input. TrueLung can be used for clinical research in cystic fibrosis and might be applied across various lung diseases.
dc.description.sponsorshipInstitute of Diagnostic, Interventional and Paediatric Radiology
dc.description.sponsorshipClinic of Paediatric Medicine
dc.identifier.doi10.48620/74906
dc.identifier.pmid39304382
dc.identifier.publisherDOI10.1016/j.zemedi.2024.08.001
dc.identifier.urihttps://boris-portal.unibe.ch/handle/20.500.12422/125344
dc.language.isoen
dc.publisherElsevier
dc.relation.ispartofZeitschrift für Medizinische Physik
dc.relation.issn0939-3889
dc.subjectCystic fibrosis
dc.subjectFunctional imaging
dc.subjectLung MRI
dc.subjectPediatrics
dc.subjectPerfusion
dc.subjectVentilation
dc.subject.ddc600 - Technology::610 - Medicine & health
dc.titleAn automated pipeline for computation and analysis of functional ventilation and perfusion lung MRI with matrix pencil decomposition: TrueLung.
dc.typearticle
dspace.entity.typePublication
dspace.file.typetext
oairecerif.author.affiliationClinic of Paediatric Medicine
oairecerif.author.affiliationInstitute of Diagnostic, Interventional and Paediatric Radiology
oairecerif.author.affiliationClinic of Paediatric Medicine
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.description.ispublishedinpress
unibe.refereedtrue
unibe.subtype.articlejournal

Files

Original bundle
Now showing 1 - 1 of 1
Name:
1-s2.0-S0939388924000849-main.pdf
Size:
4.03 MB
Format:
Adobe Portable Document Format
File Type:
text
License:
https://creativecommons.org/licenses/by/4.0
Content:
published

Collections