• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Intraoperative determination of the load-displacement behavior of scoliotic spinal motion segments: preliminary clinical results

Intraoperative determination of the load-displacement behavior of scoliotic spinal motion segments: preliminary clinical results

Details
Files
DOI
10.7892/boris.11460
Publisher DOI
10.1007/s00586-012-2164-8
PubMed ID
22315034
Abstract
Introduction: Spinal fusion is a widely and successfully performed strategy for the treatment of spinal deformities and degenerative diseases. The general approach has been to stabilize the spine with implants so that a solid bony fusion between the vertebrae can develop. However, new implant designs have emerged that aim at preservation or restoration of the motion of the spinal segment. In addition to static, load sharing principles, these designs also require a profound knowledge of kinematic and dynamic properties to properly characterise the in vivo performance of the implants.

Methods: To address this, an apparatus was developed that enables the intraoperative determination of the load–displacement behavior of spinal motion segments. The apparatus consists of a sensor-equipped distractor to measure the applied force between the transverse processes, and an optoelectronic camera to track the motion of vertebrae and the distractor. In this intraoperative trial, measurements from two patients with adolescent idiopathic scoliosis with right thoracic curves were made at four motion segments each.

Results: At a lateral bending moment of 5 N m, the mean flexibility of all eight motion segments was 0.18 ± 0.08°/N m on the convex side and 0.24 ± 0.11°/N m on the concave side.

Discussion: The results agree with published data obtained from cadaver studies with and without axial preload. Intraoperatively acquired data with this method may serve as an input for mathematical models and contribute to the development of new implants and treatment strategies.
Date Issued
2012
Publication Type
Article
Subject(s)
500 Science > 570 Life sciences; biology
600 Technology > 610 Medicine & health
Author(s)
Reutlinger, Christoph  
Institut für chirurgische Technologien und Biomechanik (ISTB)  
Hasler, Carol
Scheffler, Klaus
Büchler, Philippe  orcid-logo
Institut für chirurgische Technologien und Biomechanik (ISTB)  
Additional Credits
Institut für chirurgische Technologien und Biomechanik (ISTB)  
Journal
European spine journal
Publisher
Springer-Verlag
ISSN
0940-6719
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 24f0a9 [ 4.09. 8:55]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • BORIS Portal & Open Science
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo
Repository logo COAR Notify