• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Application and calculation methods of dynamic compliance in anaesthetised dogs, a scoping review.

Application and calculation methods of dynamic compliance in anaesthetised dogs, a scoping review.

Details
Files
DOI
10.48620/87273
Publisher DOI
10.1016/j.vaa.2025.01.011
PubMed ID
40175245
Abstract
Objectives
To record the terms, definitions, and abbreviations used in the literature, investigate the rationale for employing dynamic compliance (Cdyn) in studies of anaesthetised dogs with mechanically ventilated lungs, and identify the methods used to calculate Cdyn.Databases Used
A comprehensive search across Medline, PubMed, Scopus, and CAB Abstracts databases identified studies using keywords related to canine species, anaesthesia, Cdyn, and the respiratory system. Reference lists from recent publications (2010-2024) focusing on respiratory mechanics in dogs were also reviewed. Following duplicate removal, a two-step screening process was employed. This involved reviewing titles and abstracts, followed by full-text retrieval based on predefined eligibility criteria, concentrating on studies involving anaesthetised dogs with closed chests where Cdyn was measured. Data extraction included terms, definitions, measurement equipment, and study applications.Conclusions
Of 362 initial documents, 186 duplicates were removed, leaving 176 for abstract screening. Of these, 122 full texts were retrieved, with 54 meeting inclusion criteria. Most studies were published between 1970 and 2002, with only five published after 2010. In 49/54 studies, dogs were used as animal models for translational research. Whole-body plethysmographs and pneumotachographs were commonly used to evaluate tidal volume for the calculation of Cdyn; the sampling site of airway pressure varied. In 43/54 papers, oesophageal or pleural pressure was measured to determine transpulmonary pressure, suggesting that Cdyn of the lung was monitored, although this was not always explicitly stated. The three most recent studies involved clinical patients, using Cdyn of the respiratory system displayed by respiratory modules integrated into ventilators or multiparametric physiological monitors. Future research should establish clear protocols for measuring Cdyn to enhance understanding and characterization for both research and clinical purposes.
Date Issued
2025-05
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Subjects
compliance
•
dogs
•
dynamic compliance
•
respiratory mechanics
•
spirometry
•
ventilation
Language(s)
en
Author(s)
Raillard, Mathieu  
Levionnois, Olivier  orcid-logo
Department of Clinical Veterinary Medicine, Anaesthesiology  
Department of Clinical Research and Veterinary Public Health, Veterinary Pharmacology and Toxicology  
Mosing, Martina
Raisis, Anthea
Additional Credits
Department of Clinical Veterinary Medicine, Anaesthesiology  
Department of Clinical Research and Veterinary Public Health, Veterinary Pharmacology and Toxicology  
Journal
Veterinary Anaesthesia and Analgesia
Publisher
Elsevier
ISSN
1467-2995
1467-2987
Access(Rights)
restricted
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 24f0a9 [ 4.09. 8:55]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • BORIS Portal & Open Science
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo
Repository logo COAR Notify