  3. Accuracy of volume measurements by a clinical spirometer in multiple veterinary hospitals
 

Accuracy of volume measurements by a clinical spirometer in multiple veterinary hospitals

Options
  • Details
Project description
Spirometry devices, which are components of many anaesthesia machines, are commonly used to assess lung mechanics during anaesthesia. Spirometry calibration usually adheres to manufacturer recommendations without established guidelines. Although more accurate and less variable than inbuilt spirometry in certain General Electric anaesthesia ventilators, near-patient spirometry lacks adequate evaluation. We assessed near-patient spirometers’ performance using Pedi-lite and D-lite flow sensors. Certified 1 L calibration syringes were used on 67 monitors located in 14 veterinary hospitals. Three consecutive inspired and expired volume values displayed by the monitors for each volume of the calibration syringe were recorded. Volumes studied were 50, 100, 150, 250, 300 mL for Pedi-lite and 150, 300, 450, 500, 750 mL for D-lite. Measured and targeted volumes were averaged, agreement error calculated. Accuracy was assessed plotting agreement errors against calibration volumes. A linear mixed-effects model was used to obtain linear regression between the error and the calibration volume.
Data Availability
Open
Contact Person
Levionnois, Olivierorcid-logo
Department of Clinical Veterinary Medicine, Anaesthesiologyorcid-logo
Contributors
Levionnois, Olivierorcid-logo
Department of Clinical Veterinary Medicine, Anaesthesiologyorcid-logo
Raillard, Mathieu Clément
Murdoch University
DOI
10.48620/7368
Organization(s)
Department of Clinical Veterinary Medicine, Anaesthesiologyorcid-logo
Murdoch University
Languages
English
Subject(s)

500 - Science::570 - ...

Keyword(s)

Spirometry

veterinary anaesthesi...

D-lite

Ped-lite

General Electrics

Rights URI
Attribution (CC BY 4.0)
Show full item
File(s)
FileFile TypeFormatSizeLicensePublisher/Copright statementContent
Volume_accuracy_readme.txtresearch dataText5.52 KBOpen
Volume_accuracy_from_spirometers_DLite.csvresearch dataCSV10.5 KBOpen
Volume_accuracy_from_spirometers_PediLite.csvresearch dataCSV9.67 KBOpen
Supplementary File(s)
FileFile TypeFormatSizeLicensePublisher/Copright statementContent
  View More
DTA file(s)
FileFile TypeFormatSizeLicensePublisher/Copright statementContent
  View More
BORIS Portal
Bern Open Repository and Information System
Build: 360c85 [14.04. 8:05]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo